ouTPuT oPTionS
11.15
CLS WAIT OUT: 0
Closing Wait Output
Entertheoutputnumbertoturnonforapproximatelyfour(4)secondswhenClosing
WaitisprogrammedasYESandthepanelsuccessfullycommunicatestheclosing
message at arming. If the closing message does not communicate successfully, this
output does not turn on.
11.16
ARM-ALARM OUT: 0
Arm-Alarm Output
Enter the output number to turn on steady when any area of the system is armed. If
an alarm occurs causing the keypads to turn Red, this output pulses and continues to
pulseforapproximatelyve(5)minutesafterthepanelisdisarmed.Enter0(zero)
to disable.
Wireless Outputs
• TheArm-AlarmOutputiscompatiblewiththeModel1117WirelessLED
AnnunciatorandtheModel1116WirelessRelayOutputconnectedtoaModel
572IndicatorLED.
• WhentheModel1117isbatteryoperated,theLEDisoffwhenthesystemis
armedtoconservebatterylife.Ifanalarmoccurs,theoutputashesquickly.
• WhenusingtheModel1116connectedtoaModel572,theLEDisonwhenthe
system is armed. If an alarm occurs, the output pulses.
• TooperatetheArm-Alarmoutputwithinonesecond,programafastresponse
numberfrom480to499.Fastresponseoperationreducesoverallwireless
output battery life.
• TooperatetheArm-Alarmoutputwithin15seconds,programaslowresponse
numberfrom450to474.Slowresponseoperationincreasesoverallwireless
output battery life.